Penta-enzyme Medical device Cleaner Concentrate

Snow-branded Multi-enzyme Cleaner Concentrate is a new generation of enzymes for an enhanced cleaning & suction action to degrade proteins,
fats, and blood residues. This penta-enzyme compounded concentrate is intended for thoroughly cleaning endoscopes,scalpel, surgical scissors,
vascular forceps, tissue forceps, intestinal forceps, probes, curettes, aspirator heads and other surgical instruments.
Availability:
Quantity:

Snow-branded Multi-enzyme Cleaner Concentrate is a new generation of enzymes for an enhanced cleaning & suction action to degrade proteins,
fats, and blood residues. This penta-enzyme compounded concentrate is intended for thoroughly cleaning endoscopes,scalpel, surgical scissors,
vascular forceps, tissue forceps, intestinal forceps, probes, curettes, aspirator heads and other surgical instruments.


The product is used for thoroughly cleaning of soft endoscope, hard endoscope, scalpel, surgical scissors, vascular forceps, tissue forceps, intestinal forceps, probes, curettes, aspirator heads and other surgical instruments.


微信图片_202210091127421

Features
Penta-enzyme compounded,
Enzyme stabilizer added,
Neutral pH
Does not contain aldehydes, phenols, chlorine or EDTA,Dissolves the biofilm,Prevents corrosion and instrument discoloration,
Effectively removes organic residues
Low-foam formulation

BENEFITS
Suction cleaner
Very economical
Compatible with heat-sensitive instruments
Compatible with most materials such as stainless steel, aluminum,glass, ceramics, hard plastics, ebonite, etc.


"bio-enzyme based concentration cleaner solution is designed to be used on:

a) manual cleaning,

b) ultrasonic cleaning and,

c) disinfection machine cleaning.


1. Dilution ratio:

Hand washing and ultrasonic cleaning: slight pollution 1:200 ;

                                                              heavily pollution 1:100 ;

Machine washing: 1:500.


2. Water temperature requirements:

manual cleaning 15 ℃ - 30 ℃ ,

machine and ultrasonic cleaning 15 ℃ - 55 ℃ .


3. Disassemble the machine, and suck, flush the lumen before soaking the lumen instruments such as soft endoscope and hard endoscope.


4. Completely immerse the contaminated instrument in the enzyme washing solution for 2-5 minutes. In case of heavily pollution, the immersion time can be appropriately extended, and then wash it by hand or washing machine.


Disposals

Flush with plenty of water to a sanitary sewer. Dispose of empty containers and packaging in accordance with local state and federal regulations.


Information concerning human and environmental exposure may be reviewed on the Safety Data Sheet(SDS) for the product. For additional information regarding incidents involving human and convironmental exposure, call +86 157 2700 5795


Previous: 
Next: 
Wuhan Snow Medical Disinfectant Co., Ltd is a leading disinfectant factory since 1999.

Quick Links

Product Category

Contact Us

Tel: +86-15827109570
Phone: +86-15827109570
Whatsapp: +86-15827109570
Add: 18, Yinhu Science & Technology Industrial Park,Dongxihu District, Wuhan, Hubei, China 430040
Copyright © 2023 Wuhan Snow Medical Disinfectant Co., Ltd. Supported by Leadong.  Sitemap. Privacy Policy